ADDRESS
30-092 Kraków, ul. L.Kmietowicza 11
LOCATION MAP
TEL +48 12644 5960
PRODUCTION PLANT
JANUSZOWICE 32-090 SŁOMNIKI
LOCATION MAP
EN
EN
PL
DE
RU
Home
About Us
Products
Pressed Gratings
Welded Gratings
Stair treads
Anti-slip gratings
Shelf gratings
Stainless gratings
Entrance gratings
Fence gratings
Spiral stairs
Ladder rungs
System clamps
Special designs
Technical informations
Load calculator - pressed gratings
Load calculator - welded gratings
Warehouse
Download
Contact us
Home
About Us
Products
Pressed Gratings
Welded Gratings
Stair treads
Anti-slip gratings
Shelf gratings
Stainless gratings
Entrance gratings
Fence gratings
Spiral stairs
Ladder rungs
System clamps
Special designs
Technical informations
Load calculator - pressed gratings
Load calculator - welded gratings
Warehouse
Download
Contact us
Load calculator - pressed gratings
DESCRIPTION
CALCULATOR
NOTE
Select the type of calculation
Complete the fields marked in blue
The calculated values are displayed in the boxes marked with green color
The values without color do not take into the calculation of a given type
Click "Calculate"
Load calculator - pressed gratings
Type of calculation
Load and Stress
Support spacing
Thickness of bearing bar
Height of bearing bar
Weight
Load
values of continuous load
concentrated load values, with the pressure face of 200x200 mm
concentrated load values, with the pressure face of 150x150 mm
concentrated load values, with the pressure face of 100x100 mm
concentrated load values, with the pressure face of 50x50 mm
Spacing of the supports
mm
Spacing of the bearing bars
16.0
22.2
33.3
44.4
55.5
66.6
77.7
88.8
99.9
mm
Spacing of the cross bars
11.1
22.2
33.3
44.4
55.5
66.6
99.9
mm
Height of the bearing bars
20
25
30
35
40
50
60
70
mm
Thickness of the bearing bars
2
3
4
5
mm
Length
mm
Width
mm
Height of the cross bars
9
12
mm
Thickness of the cross bars
2
1.5
2.5
mm
Frame
Weight
kg
fv
- deflection
cm
Fv
- load
kN/m2
Note
The calculated values are calculated based on the relationship of theoretical and determine the strength of the grating as indicative.
Concentrated loads and continous loads are allowable loads taking into account the maximum possible deflection of the grating.
Depending on the mesh size or dimensions of flat, load values are calculated from the condition of load capacity or condition of use.
The values of the dimensions of flat and mesh size should be correlated with the program production of company Kraty Mostostal Kraków.